Research Lab Tools Free lab calculators with the working shown All tools

Guide · 2 min read

Temperature Scales and Sample Storage

Celsius, kelvin and Fahrenheit and how they relate, plus the temperature bands used for storing reagents and peptide samples, from room temperature to liquid nitrogen.

Reviewed 20 Oct 2026 3 references Companion tool: T-10 Temperature

Temperatures in the lab appear in three scales: kelvin in physical chemistry, Celsius on almost every instrument, and Fahrenheit on some equipment and in older protocols. Converting between them is simple, and getting it wrong can cost a sample.

The three scales

  • Kelvin (K) is the SI base unit of thermodynamic temperature. Zero kelvin is absolute zero. Kelvin takes no degree sign: write 298.15 K.
  • Celsius (°C) is defined from the kelvin: t/°C = T/K − 273.15. A step of 1 °C is exactly a step of 1 K.
  • Fahrenheit (°F) has smaller degrees (1 °F = 5/9 K) and a different zero. Water freezes at 32 °F and boils at 212 °F at standard pressure.

Conversion formulas

K = °C + 273.15    °F = °C × 9/5 + 32    °C = (°F − 32) × 5/9

Note that −40 °C equals −40 °F, the one point where the two scales meet.

Worked examples

−20 °C → °F: −20 × 1.8 + 32 = −4 °F. In kelvin: −20 + 273.15 = 253.15 K.

−80 °C → °F: −80 × 1.8 + 32 = −112 °F.

37 °C → °F: 37 × 1.8 + 32 = 98.6 °F.

Storage temperature bands

Band °C °F Typical equipment
Controlled room temperature 15 to 25 59 to 77 Bench, cabinet
Refrigerated 2 to 8 36 to 46 Lab refrigerator
Frozen −20 (approx.) −4 Standard freezer
Ultra-low −80 (approx.) −112 Ultra-low freezer
Cryogenic −150 to −196 −238 to −321 Liquid nitrogen vapour or liquid

General storage practice for peptides

Always follow the storage conditions on the supplier’s certificate of analysis. As general laboratory practice:

  • Lyophilised solids are usually kept cold (often −20 °C or below), sealed and dry. Let a cold vial reach room temperature before opening, so moisture does not condense on the powder.
  • Solutions are less stable than solids. Divide a stock into single-use aliquots and freeze them, so each aliquot is thawed only once.
  • Sensitive residues such as Cys, Met and Trp can oxidise, and Asn and Gln can deamidate over time, especially in solution and at higher pH.
  • Freezer cycles. Frost-free freezers warm periodically to defrost. For long-term storage, a manual-defrost or ultra-low freezer is more stable.

Common mistakes

  • Writing “°K”. The kelvin has no degree sign.
  • Converting a temperature difference with the +32 offset. A difference of 10 °C is a difference of 18 °F, not 50 °F.
  • Reading a −20 °F setting as −20 °C. That is −28.9 °C, colder than intended, and the reverse mistake leaves samples too warm.

References

  1. BIPM: The International System of Units (SI Brochure, 9th edition)
  2. NIST Office of Weights and Measures: SI units – temperature
  3. NIST Special Publication 811: Guide for the Use of the International System of Units